Instrumental methods use machines to detect and measure substances
Instrumental method
A method of analysis that uses a machine to detect and measure a property of a substance.
- A chemical test, such as a flame test, depends on a person seeing and judging a colour, a precipitate or a sound.
- An instrumental method uses a machine to measure a property of the sample, and a computer usually records the result.
- Flame emission spectroscopy heats a sample in a flame and measures the light given out, which identifies the metal ions present.
- Gas chromatography separates the substances in a mixture and records the time each one takes to pass through the instrument.
- The result is a chart or table of measurements, which is then compared with results for known substances.
Hospital laboratories analyse blood samples with instruments, and water companies use them to check drinking water for traces of metal ions.
Instrumental methods are sensitive, accurate and rapid
Sensitivity
How small an amount of a substance a method of analysis can detect.
- They are sensitive, so they detect substances present in very small amounts, even in a tiny sample.
- A flame test needs enough of the metal ion to colour the flame, whereas flame emission spectroscopy detects traces far too small to see.
- They are accurate, giving measurements close to the true value, so they identify substances reliably and can show how much is present.
- The result does not depend on a person's judgement of a colour, so a yellow-orange flame cannot be mistaken for an orange-red one.
- They are rapid, so results come quickly and a machine can analyse many samples one after another, day and night.
- The main drawback is that the instruments are expensive to buy and need trained people to run them.
Do not give 'easier' or 'safer' as advantages of instrumental methods, because the accepted advantages are sensitivity, accuracy and speed.
Identifying substances by matching a reference chart
Flame emission spectroscopy
An instrumental method that heats a sample in a flame and splits the light given out into a line spectrum, which identifies the metal ions present.
Reference data
Results recorded for known substances, under the same conditions as an unknown sample, which are compared with the unknown to identify it.
- In flame emission spectroscopy, the light from the flame is split into a line spectrum, a set of bright lines at particular wavelengths.
- Each metal ion gives its own pattern of lines, like a fingerprint.
- To identify an unknown sample, compare its lines with reference spectra for known metal ions, drawn on the same scale.
- A metal ion is present only if every line in its reference spectrum appears in the spectrum of the sample.
- Lines left over after one match belong to another ion, so one spectrum can identify each ion in a mixture.
In a simplified set of reference spectra, calcium ions give a line at 423 nm423\,\text{nm}423nm and sodium ions a line at 589 nm589\,\text{nm}589nm, so a sample whose spectrum shows both lines contains calcium ions and sodium ions.
Identifying substances by matching a reference table
Retention time
The time a substance takes to pass through a gas chromatography instrument, from injection to detection.
- In gas chromatography, each substance leaves the instrument after its own retention time, measured under fixed conditions.
- The instrument records a peak for each substance, so the number of peaks shows how many substances the sample contains.
- The retention times from the sample are compared with a reference table for known substances, measured under the same conditions.
- A substance is identified when its retention time matches a reference value.
- A value that matches no reference belongs to a substance that cannot be identified from the data given.
Identifying alcohols in a sample from retention times
- Under the same conditions, ethanol has a retention time of 2.12.12.1 minutes, propan-1-ol 3.43.43.4 minutes and butan-1-ol 5.05.05.0 minutes; a sample gives peaks at 2.12.12.1 and 5.05.05.0 minutes, so identify the substances in it.
- Count the peaks: two peaks show two substances.
- The peak at 2.12.12.1 minutes matches ethanol, and the peak at 5.05.05.0 minutes matches butan-1-ol.
- No peak appears at 3.43.43.4 minutes, so the sample contains ethanol and butan-1-ol but no propan-1-ol.
- Give three advantages of instrumental methods over chemical tests.
- What does it mean for an instrumental method to be sensitive?
- How is a metal ion identified from a line spectrum?
- Why must reference data be recorded under the same conditions as the sample?
- A gas chromatogram shows three peaks; what does this tell you about the sample?